Tips and Advice

Learning to do a Backflow Testing in Adelaide is essential, as over 10,000 cases of backflow contamination are reported each year. Some of these have been proved to be fatal. Devices for Backflow prevention are required to maintain the regulations and must be installed.  Classic backflow assembly tools have test cocks and shut-off valves that must be checked annually from the date of installation or in case of relocation. Scrutinizing should be by the district’s plumbing codes. One should note that the testing kits costs high, and should decide whether renting them (Plumber of eastern suburbs in Adelaide) would be a cost-effective solution or not.

If you want to own the equipment for Backflow Testing in Adelaide, then you need to make to keep your tools clean and check them annually for calibration. Equipment and models from any brand should possess a 0 to 15 psi range and a working pressure of 500 psi.  Several testing kits are marketed along with gauge, hoses and fittings. There are various types of backflow testing equipment that are available in the market from multiple manufacturers and marketers.  Some of the better-known Backflow Preventer Test Kits providing backflow prevention requirements:

  • Model TK-7
  • Model TK-9A
  • Model TK-99D Delta Lite

First and foremost step for Backflow Testing in Adelaide is to shut down the water supply. It’s better to inform the affected people in the house to save water until backflow testing is completed and the water pressure is restored.

There are two different kinds of backflow devices. One with a reduced pressure principle and the other one are the double check valves. Scrutinize the kind of device with which you will be testing. Scrutinize the direction of water flow. Text messages or Arrows are provided by the manufacturer on the device, through which you can find the direction.

Maintain the number of test cocks and bushings that you need while Backflow Testing in Adelaide.  Ensure that they are clean and free of dust. Now we should shut down the valve downstream.  Wait for several minutes while testing at minimal pressure devices before hooking up test kit hoses. Water leaking from the valve (Leaking taps in Adelaide) denotes that first check valve might have fouled & asked for servicing before you go further. This may cost you some time, but there is no other way. Water leakage from the double check valves does not indicate any concern.

Test kit hoses for Backflow Testing in Adelaide have inlaid or inbuilt instructions. It’s better to follow the instructions while hooking them up according to the device that you are testing. As there are different tests according to devices, each local municipality, county and state has its testing regulations. That’s why you are advised to access their guideline and follow them accordingly. You can turn on some tips for checking the progress.  Water should run back through the system.  Verify if the relief valve opens. If it does, you should replace it.  After this, you should look for water pressure inside the valve by using the gauge. Rising pressure indicates the water is struggling to flow backwards, and you have to replace the valve.

When it comes to different Backflow Testing in Adelaide, there are several devices to choose from. You will depend on what kind of water backflow situation you are preventing. Following is a list of popular ones with explanations.

Atmospheric Vacuum Breaker – This device is an elbow-shaped device, angled at 90 degrees. A valve inside it prevents water backflow.  This system is based on water pressure and requires to be installed at least six inches above from the place of downstream.  It can be placed on PVC a pipe which will make it difficult for testing.

Chemigation Valve – This type of valve is used for Backflow Testing in Adelaide agricultural areas. It is meant for keeping a clean water supply along with different farming pesticides and other chemicals. Use of these products is called chemigation. There are various components of this valve. The check valve itself has a flapper operated by spring, which allows water to flow only in one direction.  There are a low-pressure drain and air vacuum release valve inside the device. The last component of the device is the injection port.  This is where the chemicals are introduced to go downstream of the check valve.

Hydrostatic Loop – Arranging pipes in a vertical form is referred to as a hydrostatic loop while Backflow Testing in Adelaide. In this set up the loop should be higher than 33 feet for functioning correctly. This design gives the capability of syphoning and backflow water system.

Double Check Valve – This valve is typically seen on the sprinkler systems installed on lawn or fire sprinkler systems. There is a ball or gate valve assembled on both ends. This allows for testing and isolation. Normal & reverse flow is possible in this plug.

Reduced Pressure Zone Device – Abbreviated to RPZD, it is also effective in preventing the contamination of water supplies while Backflow Testing in Adelaide. Unlike other devices, it is designed for hazards levels. High-level hazards are defined as a situation where the water backflow can seriously harm individuals. Some cities recommend these valves should be tested once a year by certified technicians. This device has a chamber that lies between two independent check valves for monitoring pressure.  Excess pressure is released through an additional drain, while the monitor chamber remains at a lower pressure than water supply pressure.

Air Gap – The last prevention device in the system for Backflow Testing in Adelaide is something that is found in almost all homes. It is the faucet of your home where there is a critical air gap between the faucet head and the sink. As ice freezes in the winter, people are advised to turn the water on at night. The movement of the water prevents it from freezing, expanding, and bursting the pipes. It also relieves pressure by allowing the water a place to go if pressure builds in the pipes from partial freezing. This article will help you in Testing on your own, without the being depending on someone.